System SP Tables-2
SM Appendix 4-31 D017/D018/D019/D020/D084/D085
Appendix:
Service
Program
Mode
2998*
PCU Reverse Rotation Time DFU
1
Wait Time
Adjusts the waiting time for starting to rotate the drum in reverse after the
end of each job. The wait time calculation formula is as follows.
[0 to 999 / 600/ 1]
This SP is adjusted in units of 30 ms (1 step = 30 ms, 2 steps = 60 ms, etc.)
If "0" is selected, the drum reverses immediately at the end of the job.
2
Reverse Time
Adjusts the drum reverse rotation time.
[0 to 99 / 60/ 1]
This SP is adjusted in units of 60 ms (1 step = 6 ms, 2 steps = 12 ms, etc.)
If "0" is selected, the drum does not reverse at the end of the job.
3
Brake Time
Adjusts the length of time of braking to stop reverse rotation of the drum.
[0 to 99/60/1]
This SP is adjusted in units of 6 ms (1 step = 6 ms, 2 steps = 12 ms, etc.)
If "0" is selected, the drum stops reverse rotation immediately.
Note: Adjust the SP only if the PCU makes noise during braking when the
drum rotation slows. To reduce or eliminate the noise, select a lower setting
to reduce the braking time.