System SP Tables-4
SM Appendix 4-61 D017/D018/D019/D020/D084/D085
Appendix:
Service
Program
Mode
4678
Gain Adjustment Display
Displays the factory setting values of the gain adjustment for Green.
1 Factory Setting: GE Color
[0 to 255 / 0 / 1 digit/step]
2 Factory Setting: GO Color
3 Factory Setting: GE BW
4 Factory Setting: GO BW
4679
Gain Adjustment Display
Displays the factory setting values of the gain adjustment for Blue.
1 Factory Setting: BE Color
[0 to 255 / 0 / 1 digit/step
2 Factory Setting: BO Color
3 Factory Setting: BE BW
4 Factory Setting: BO BW
4685
Gray Balance Set: R DFU
Adjusts the gray balance of the red signal for each scanning mode.
1 Book Read
[-512 to 511 / -240 / 1 digit/step]
2 DF Read
4686
Gray Balance Set: G DFU
Adjusts the gray balance of the green signal for each scanning mode.
1 Book Read
[-512 to 511 / -240 / 1 digit/step]
2 DF Read