System SP Tables-7
D017/D018/D019/D020/D084/D085 4-164 SM Appendix
4.7 SYSTEM SP TABLES-7
4.7.1 SP7XXX: DATA LOG
7001*
Main Motor Operation Time
The number of prints and drive time for drum revolutions can be obtained
by counting the main motor revolution time. If the amount of the time
required for the drum to revolve to print 1 copy increases, this data
combined with the number of copies can be used to analyze problems and
could be useful for future product development.
Display: 0000000 to 9999999 min.
7401*
Total SC Counter
Displays the total number of service calls that have occurred.
7403* SC History
1 Latest
Displays the most recent 10 service calls.
2 Latest 1
3 Latest 2
4 Latest 3
5 Latest 4
6 Latest 5
7 Latest 6
8 Latest 7
9 Latest 8
10 Latest 9