UPPER LIMIT, RIGHT TRAY PAPER END, AND RELAY SENSORS
SM 17 B391
Large
Capacity Tray
B391
3.9 UPPER LIMIT, RIGHT TRAY PAPER END, AND
RELAY SENSORS
1. Remove the paper feed unit (see Paper Feed Unit Replacement).
2. Replace the required sensor.
• Upper limit [A]
• Relay [B]
• Right tray paper end [C]
NOTE: When replacing the upper limit [A] and paper end sensor [C], please be
sure to do so while pushing the release lever [D].
B391R111.WMF
[A]
[B]
[C]
[D]