Error Codes
SM 27 D361/D510
D361/D510
Fax Option
Type
3350/3351
Code Meaning Suggested Cause/Action
0-84
The line was
disconnected due to
abnormal signaling in
V.34 phase 4 – control
channel start-up.
The signal did not stop within 10 s.
Turn off the machine, then turn it back on.
If the same error is frequent, replace the FCU.
0-85
The line was
disconnected due to
abnormal signaling in
V.34 control channel
restart.
The signal did not stop within 10 s.
Turn off the machine, then turn it back on.
If the same error is frequent, replace the FCU.
0-86
The line was
disconnected because
the other terminal
requested a data rate
using MPh that was not
available in the currently
selected symbol rate.
The other terminal was incompatible.
Ask the other party to contact the
manufacturer.
0-87
The control channel
started after an
unsuccessful primary
channel.
The receiving terminal restarted the control
channel because data reception in the primary
channel was not successful.
This does not result in an error
communication.
0-88
The line was
disconnected because
PPR was
transmitted/received 9
(default) times within the
same ECM frame.
Try using a lower data rate at the start.
Try adjusting the cable equalizer setting.