Bit Switches - 6
SM 155 D361/D510
D361/D510
Fax Option
Type
3350/3351
IP Fax Switch 08 (SP No. 1-111-009)
No. Function Comments
0-1
T1 timer adjustment
Adjusts the T1 timer.
The default is "00" (35 seconds).
Bit 1 Bit 0
0 0 35 s
0 1 40 s
1 0 50 s
1 1 60 s
2-3
T4 timer adjustment
Adjust the T4 timer.
The default is "00" (3 seconds).
Bit 3 Bit 2
0 0 3 s
0 1 3.5 s
1 0 4 s
1 1 5 s
4-5
T0 timer adjustment
Adjusts the fail safe timer. This timer sets
the interval between "setup" data
transmission and T.38 phase decision. If
your destination return is late on the
network or G3 fax return is late, adjust the
longer interval timer.
The default is "00" (75 seconds).
Bit 5 Bit 4
0 0 75 s
0 1 120 s
1 0 180 s
1 1 240 s
6-7 Not used Do not change these settings.