NCU Parameters
SM 161 D361/D510
D361/D510
Fax Option
Type
3350/3351
Address Function Unit Remarks
68052B Busy tone OFF time: range 1
68052C Busy tone ON time: range 2
68052D Busy tone OFF time: range 2
68052E Busy tone ON time: range 3
68052F Busy tone OFF time: range 3
20 ms
680530 Busy tone ON time: range 4
680531 Busy tone OFF time: range 4
680532
Busy tone continuous tone detection
time
680533
Busy tone signal state time tolerance for all ranges, and number of cycles
required for detection (a setting of 4 cycles means that ON-OFF-ON or
OFF-ON-OFF must be detected twice).
Tolerance (±)
Bit 1 Bit 0
0 0 75%
0 1 50%
1 0 25%
1 1 12.5%
Bits 2 and 3 must always be kept at 0.
Bits 7, 6, 5, 4 - number of cycles required for cadence detection
680534
International dial tone frequency
upper limit (high byte)
Hz (BCD)
If both addresses contain
FF(H), tone detection is
disabled.
680535
International dial tone frequency
upper limit (low byte)