NCU Parameters
SM 169 D361/D510
D361/D510
Fax Option
Type
3350/3351
Address Function Unit Remarks
6805AD
Number of CNG cycles required
for detection
The data is coded in the
same way as address
680533.
6805AE Not used
Do not change the
settings.
6805AF
Acceptable AI short protocol
tone (800Hz) detection
frequency upper limit (high byte)
Hz (BCD)
If both addresses contain
FF(H), tone detection is
disabled.
6805B0
Acceptable AI short protocol
tone (800Hz) detection
frequency upper limit (low byte)
6805B1
Acceptable AI short protocol
tone (800Hz) detection
frequency lower limit (high byte)
Hz(BCD)
If both addresses contain
FF(H), tone detection is
disabled.
6805B2
Acceptable AI short protocol
tone (800Hz) detection
frequency lower limit (low byte)
6805B3
Detection time for 800 Hz AI
short protocol tone
20 ms Factory setting: 360 ms
6805B4 PSTN: Tx level from the modem -N – 3 dBm
SP2-103-002 (parameter
01).
6805B5
PSTN: 1100 Hz tone
transmission level
- N 6805B4 - 0.5N 6805B5 –3.5 (dB)
See Note 7.
6805B6
PSTN: 2100 Hz tone
transmission level
- N6805B4 - 0.5N 6805B6 –3 (dB)
See Note 7.

Table of Contents

Related product manuals