Dedicated Transmission Parameters
SM 175 D361/D510
D361/D510
Fax Option
Type
3350/3351
Switch 00
Function and Comments
ITU-T T1 time (for PSTN G3 mode)
If the connection time to a particular terminal is longer than the NCU parameter setting,
adjust this byte. The T1 time is the value stored in this byte (in hex code), multiplied by 1
second.
Range: 0 to 120 s (00h to 78h)
FFh - The local NCU parameter factory setting is used.
Do not program a value between 79h and FEh.
Switch 01
No Function Function
0
to
4
Tx level
If communication with a particular
remote terminal often contains errors,
the signal level may be inappropriate.
Adjust the Tx level for communications
with that terminal until the results are
better.
If the setting is "Disabled", the NCU
parameter 01 setting is used.
Do not use settings other than
listed on the left.
Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0 0 0 0 0 0
0 0 0 0 1 -1
0 0 0 1 0 -2
0 0 0 1 1 -3
0 0 1 0 0 -4
. . . and so on until . . .
0 1 1 1 1 -15
If all five bits are at 1, the setting is
"Disabled".
5
to
Cable equalizer
Use a higher setting if there is signal
loss at higher frequencies because of
Bit 7 Bit 6 Bit 5