SC Tables
SM Appendix 4-69 D037/D038/D040/D041
Appendix:
Service Call
Conditions
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Software performance error
The software makes an unexpected operation.
Defective software
Defective controller
Software error
1. Turn the main switch off and on.
2. Reinstall the controller and/or engine main firmware.
990
CTL
D
See Note 1 at the end of the SC table.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Software continuity error
The software has attempted to perform an unexpected operation.
However, unlike SC 990, the object of the error is continuity of the
software.
Software program error
Internal parameter incorrect, insufficient working memory.
991
CTL
C
This SC is not displayed on the LCD (logging only).
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Undefined error
Defective software program
992
CTL
D
An error undetectable by any other SC code occurred
Rev. 01/2009