System Service Mode
SM Appendix 9-13 D037/D038/D040/D041
Appendix:
SP Mode
Tables
The pressure roller has one lamp.
[Ready Temp Setting]
1108
Japan use only
007 Ready Temp Time *ENG
[22 to 60 / 22 / 0.1 sec/step]
1109 [Fusing Nip Band Check]
001 Execute -
[0 or 1 / 0 / 1]
Executes the nip band measurement
between fusing belt and pressure roller.
If the nip band width is not 8 mm, and
fusing is not good, replace the pressure
roller or install a new fusing unit.
Pre-Idling Time *ENG
[0 to 120 / 0 / 1 sec/step]
002
Specifies the fusing rotation time before executing SP1109-001.
Stop Time * ENG
[5 to 30 / 20 / 1 sec/step]
003
Specifies the time for measuring the nip.
1112 [Environmental Correct: Fusing]
Temp.: Threshold: Low *ENG
[10 to 23 / 17 / 1 deg/step]
001
Specifies the threshold temperature for low temperature condition.
Temp.: Threshold: High *ENG
[24 to 40 / 30 / 1 deg/step]
002
Specifies the threshold temperature for high temperature condition.
Low Temp. Correction *ENG
[0 to 15 / 5 / 1 deg/step]
003
Specifies the temperature correction for the heating roller. When the low
temperature condition (specified with SP1112-001) is detected, the value of this
SP is added to the heating roller temperature.