System Service Mode
D037/D038/D040/D041 9-14 SM Appendix
High Temp. Correction *ENG
[0 to 15 / 5 / 1 deg/step]
004
Specifies the temperature correction for the heating roller. When the high
temperature condition (specified with SP1112-002) is detected, the value of this
SP is subtracted from the heating roller temperature.
005 Offset Temp:Low *ENG
[0 to 15 / 6.5 / 0.1 deg/step]
006 Offset Temp:High *ENG
[0 to 15 / 5 / 0.1 deg/step]
1113 [Stand-by Mode Setting]
001 Wait Time AF Ready *ENG
[0 to 60 / 20 / 1 sec/step]
Wait Time AF Recovery *ENG
[0 to 60 / 10 / 1 sec/step]
003
Specifies the time for keeping the target temperature after recovery
(SP1105-083) without any jobs.
004 Wait Time AF Job *ENG
[0 to 60 / 10 / 1 sec/step]
005 P-Roll Thresh AF Ready *ENG
006 P-Roll Thresh AF Job *ENG
[0 to 160 / 100 / 1 deg/step]
008 ON/OFF Time SW Timer *ENG
[0 to 999 / 300 / 1 sec/step]
1115 [Stand-by Idling]
Interval *ENG
[0 to 240 / 60 / 1 min/step]
001
Specifies the interval between idling during stand-by mode.
This idling during the stand-by mode prevents the roller deformation.
Idling Time *ENG
[0 to 60 / 2 / 0.1 sec/step]
002
Specifies the length of each idling operation during stand-by mode.
003 Idling Speed *ENG
[0 to 1 / 0 / 1 mm/sec/step]
1116 [Fusing Temp Change]