System Service Mode
D037/D038/D040/D041 9-26 SM Appendix
001 Environmental Target: Bk *ENG
002 Environmental Target: C *ENG
[0 to 3000 / 740 / 10 ųA/step]
003 Environmental Target: M *ENG
[0 to 3000 / 760 / 10 ųA/step]
004 Environmental Target: Y *ENG
[0 to 3000 / 750 / 10 ųA/step]
[Charge AC A: MM] Charge Roller AC Current Adjustment for MM
(Color)
2009
Displays/sets the AC current target of the charge roller for MM environment
(Middle temperature and Middle humidity). DFU
001 Environmental Target: Bk *ENG
002 Environmental Target: C *ENG
003 Environmental Target: M *ENG
[0 to 3000 / 790 / 10 ųA/step]
004 Environmental Target: Y *ENG
[0 to 3000 / 850 / 10 ųA/step]
[Charge AC A: MH] Charge Roller AC Current Adjustment for MH
(Color)
2010
Displays/sets the AC current target of the charge roller for MH environment
(Middle temperature and High humidity). DFU
001 Environmental Target: Bk *ENG
002 Environmental Target: C *ENG
[0 to 3000 / 820 / 10 ųA/step]
003 Environmental Target: M *ENG
[0 to 3000 / 840 / 10 ųA/step]
004 Environmental Target: Y *ENG
[0 to 3000 / 880 / 10 ųA/step]
[Charge AC A: HH] Charge Roller AC Current Adjustment for HH
(Color)
2011
Displays/sets the AC current target of the charge roller for HH environment

Table of Contents