System Service Mode
SM Appendix 9-27 D037/D038/D040/D041
Appendix:
SP Mode
Tables
(High temperature and High humidity). DFU
001 Environmental Target: Bk *ENG
002 Environmental Target: C *ENG
[0 to 3000 / 860 / 10 ųA/step]
003 Environmental Target: M *ENG
[0 to 3000 / 840 / 10 ųA/step]
004 Environmental Target: Y *ENG
[0 to 3000 / 940 / 10 ųA/step]
2012 [Charge Output Control]
001 AC Voltage *ENG
Selects the AC voltage control type.
[0 or 1 / 0 / 1 /step]
0: Process control
1: Manual control (AC voltages are
decided with SP2006.)
2013 [Envir. Correct:PCU]
001 Envir. Range:FC:Display *ENG
Displays the environmental condition,
which is measured in absolute
humidity.
[1 to 5 / / 1 /step]
1: LL (LL <= 4.3 g/m
3
)
2: ML (4.3 < ML <= 11.3 g/m
3
)
3: MM (11.3 < MM <= 18.0 g/m
3
)
4: MH (18.0 < MH <= 24.0 g/m
3
)
5: HH (24.0 g/m
3
< HH)
002 Forced Setting *ENG
Selects the environmental condition
manually.
[0 to 5 / 0 / 1 /step]
0: The environmental condition is
determined automatically.
1: LL, 2: ML, 3: MM, 4: MH, 5: HH
003 Absolute Humidity: Thresh 1 *ENG Changes the humidity threshold