System Service Mode
D037/D038/D040/D041 9-54 SM Appendix
002 Plain: M *ENG
003 Plain: C *ENG
004 Plain: Y *ENG
009 Thick 2: Bk *ENG
010 Thick 2: M *ENG
011 Thick 2: C *ENG
012 Thick 2: Y *ENG
[Ambient Temp/Hum:Display]
2241
Displays the environment temperature and humidity.
001 Temperature - [–1280 to 1270 / - / 0.1deg/step]
002 Relative Humidity - [0 to 1000 / - / 0.1 %RH/step]
003 Absolute Humidity - [0 to 100 / - / 0.1 g/m
3
/step]
2302
[Env. Correct:Transfer]
Environmental Correction: Image Transfer Belt Unit
Forced Setting *ENG
[0 to 6 / 0 / 1 /step]
002
Sets the environment condition manually.
0: Automatic environment control
1: LL (Low temperature/ Low humidity)
2: ML (Middle temperature/ Low humidity)
3: MM (Middle temperature/ Middle humidity)
4: MH (Middle temperature/ High humidity)
5: HH (High temperature/ High humidity)
Absolute Humidity: Threshold 1 *ENG
[0 to 100 / 4 / 0.01 g/m
3
/step]
003
Adjusts the threshold value between LL and ML.