System Service Mode
SM Appendix 9-153 D037/D038/D040/D041
Appendix:
SP Mode
Tables
[0 to 5 / 0.9 / 0.01 mg/cm
2
/kV /step]
006 C (Target Display) *ENG
Displays the target development gamma
for C/M/Y.
[0 to 5 / 0.8 / 0.01 mg/cm
2
/kV /step]
007 M (Target Display) *ENG
[0 to 5 / 0.8 / 0.01 mg/cm
2
/kV /step]
008 Y (Target Display) *ENG
[0 to 5 / 0.77 / 0.01 mg/cm
2
/kV /step]
009 Bk (Standard Target Set) *ENG
Displays the standard target development
gamma for each color.
[0 to 5 / 0.9 / 0.01 mg/cm
2
/kV /step]
010 C (Standard Target Set) *ENG
011 V (Standard Target Set) *ENG
012 Y (Standard Target Set) *ENG
[0 to 5 / 0.8 / 0.01 mg/cm
2
/kV /step]
013 Environmental Correction *ENG
Turns on or off the environmental
correction for target development
gamma.
[0 or 1 / 1 / - ]
0: Not Correct, 1: Correct
014 K (Max Correction) *ENG
015 C (Max Correction) *ENG
016 M (Max Correction) *ENG
017 Y (Max Correction) *ENG
[0 to 5 / 0.1 / 0.01 mg/cm2/kv/step]
018 K (Max Abs Hum) *ENG
019 C (Max Abs Hum) *ENG
020 M (Max Abs Hum) *ENG
021 Y (Max Abs Hum) *ENG
[1 to 99 / 15 / 1 g/m3/step]