System Service Mode
D037/D038/D040/D041 9-152 SM Appendix
004 Relative Humidity Range *ENG
[0 to 99 / 50 / 1 %RH/step]
005 Absolute Humidity Range *ENG
[0 to 99 / 6 / 1 g/m
3
/step]
[Rapi_timer]
100
[Time Setting] *ENG
[0 to 255 / 30 / 1 sec/step]
[Non-use Time Process Control Setting]
3531
Adjusts the threshold for the process control at stand-by.
When the current condition has changed by more than the values of these SPs
when compared with the conditions at the previous operation, the process
control at stand-by is executed.
001 Non-use Time Setting *ENG
[0 to 1440 / 360 / 1 minute/step]
002 Temp. Range *ENG
[0 to 99 / 10 / 1°C/step]
003 Relative Humidity Range *ENG
[0 to 99 / 50 / 1 %RH/step]
004 Absolute Humidity Range *ENG
[0 to 99 / 6 / 1 g/m
3
/step]
005
Maximum Execution
Number
*ENG
Adjusts the maximum execution time for
the process control at stand-by.
[0 to 99 / 10 / 1 time/step]
3611 [Dev. Gamma: Display/Set]
001 Bk (Current) *ENG
Displays the current development gamma
for Bk
[0 to 5 / 0.9 / 0.01 mg/cm
2
/kV /step]
002 C (Current) *ENG
003 M (Current) *ENG
004 Y (Current) *ENG
Displays the current development gamma
for C/M/Y.
[0 to 5 / 0.8 / 0.01 mg/cm
2
/kV /step]
005 Bk (Target Display) *ENG
Displays the target development gamma
for Bk.