System Service Mode
SM Appendix 9-151 D037/D038/D040/D041
Appendix:
SP Mode
Tables
[Toner End Prohibition Setting]
3519
Enables or disables each adjustment at toner near end.
001 Process Control *ENG
002 MUSIC *ENG
003 TC Adjustment *ENG
[0 or 1 / 1 / 1/step]
0: Permit (adjustment is done even toner
near end condition)
1: Forbid (adjustment is not done at toner
near end condition)
3520 [ITB Idling Rotation]
001 Temperature: High *ENG
002 Temperature: Medium *ENG
003 Temperature: Low *ENG
004 Temperature: L: Power ON *ENG
[0 or 3 / 0 / 1 revolution/step]
005 Temp. Range Thresh:T2 *ENG
[20 or 30 / 30 / 1 deg/step]
006 Temp. Range Thresh:T2 *ENG
[0 or 15 / 15 / 1 deg/step]
010
Temp. Thresh Temp.
Thresh:High
*ENG
[0 or 50 / 30 / 1 deg/step]
011
Temp. Thresh Temp.
Thresh:Low
*ENG
[0 or 50 / 15 / 1 deg/step]
[Initial Process Control Setting]
3522
Adjusts the threshold for the process control at power on.
When the current condition has changed by more than the values of these SPs
when compared with the conditions at the previous operation, the process
control at power on is executed.
002 Non-use Time Setting *ENG
[0 to 1440 / 360 / 1 minute/step]
003 Temperature Range *ENG
[0 to 99 / 10 / 1°C/step]