System Service Mode
D037/D038/D040/D041 9-150 SM Appendix
value, toner is applied to the transfer belt at set intervals during the job to
prevent the blade from flipping over.
001
Execution Temp.
Threshold
*ENG
[0 to 50/ 40 / 1°C/step]
3518 [Image Adj. Execution Flag] DFU
001 Toner End Recovery: Bk *ENG
002 Toner End Recovery: C *ENG
003 Toner End Recovery: M *ENG
004 Toner End Recovery: Y *ENG
005 Vsg Adjustment *ENG
006 Developer Agitation *ENG
[0 or 1 / 0 / 1/step]
0: OFF. 1: ON
007 Process Control *ENG
[0 to 2 / 0 / 1/step]
0: OFF. 1: ON (once), 2: ON (twice)
008 MUSIC *ENG
[0 to 2 / 0 / 1/step]
0: OFF. 1: ON (once), 2: ON (twice)
009 Drum Phase Adj. *ENG
010 Charge AC Control *ENG
011 Blade Damage Prevention *ENG
[0 or 1 / 0 / 1/step]
0: OFF. 1: ON
012 Vsg Average Error *ENG
[0 or 1 / 0 / 1/step]
Sets “1”, when the following values
shows.
Vsg_reg_ave:
3.5 ≤ Vsg_reg_ave ≤ 4.5 or
Vsg_dif_ave:
0.0 ≤ Vsg_dif_ave ≤ 0.5