System Service Mode
D037/D038/D040/D041 9-156 SM Appendix
010 Low Speed:C *ENG
011 Low Speed:M *ENG
012 Low Speed:Y *ENG
[HST Controll Setting]
TD Sensor: Toner Concentration Control Setting
3710
Selects the toner concentration control method by HST memory, which is in the
TD sensor.
001 Control Selection *ENG
[0 or 1 / 1 / - ]
0: Not Use, 1: Use
[HST Control: Bk]
3711
Displays the factory settings of the black PCU.
001 Vcnt *ENG
[0 to 5 / 4 / 0.1 V/step]
002 Vt *ENG
[0 to 5 / 2.5 / 0.1 V/step]
003 Sensitivity: HL *ENG
[1.22 to 3.77 / 2.5 / 0.01 V/step]
004 Sensitivity: HM *ENG
[0 to 2.55 / 1.3 / 0.01 V/step]
005 Sensitivity: ML *ENG
[0 to 2.55 / 1.2 / 0.01 V/step]
006 Set Detection *ENG
[0 to 5 / 1 / 0.1 V/step]
007 Without Developer *ENG
[0 to 5 / 1.2 / 0.1 V/step]
008 With Developer *ENG
[0 to 5 / 1.3 / 0.1 V/step]
009 Serial Number 1 *ENG
010 Serial Number 2 *ENG
[0 to 255 / - / 1 V/step]
011 Adjustment: Vt *ENG
012 Adjustment: Vtref *ENG
[0 to 5 / 3 / 0.1 V/step]