EasyManua.ls Logo

Ricoh D037 - Page 691

Ricoh D037
1171 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System Service Mode
SM Appendix 9-157 D037/D038/D040/D041
Appendix:
SP Mode
Tables
013 Adjustment: Vtcnt *ENG
[0 to 5 / 4 / 0.01 V/step]
014 Adjustment: Gamma *ENG
[0 to 2.55 / 0 / 0.01 mg/cm
2
/kV /step]
015 Adjustment: Vcnt Result *ENG
[0 to 9 / 9 / 1 /step]
[HST Control: C]
3712
Displays the factory settings of the magenta PCU.
001 Vcnt *ENG
[0 to 5 / 4 / 0.1 V/step]
002 Vt *ENG
[0 to 5 / 2.5 / 0.1 V/step]
003 Sensitivity: HL *ENG
[1.22 to 3.77 / 2.5 / 0.01 V/step]
004 Sensitivity: HM *ENG
[0 to 2.55 / 1.3 / 0.01 V/step]
005 Sensitivity: ML *ENG
[0 to 2.55 / 1.2 / 0.01 V/step]
006 Set Detection *ENG
[0 to 5 / 1 / 0.1 V/step]
007 Without Developer *ENG
[0 to 5 / 1.2 / 0.1 V/step]
008 With Developer *ENG
[0 to 5 / 1.3 / 0.1 V/step]
009 Serial Number 1 *ENG
010 Serial Number 2 *ENG
[0 to 255 / - / 1 V/step]
011 Adjustment: Vt *ENG
012 Adjustment: Vtref *ENG
[0 to 5 / 3 / 0.1 V/step]
013 Adjustment: Vtcnt *ENG
[0 to 5 / 4 / 0.01 V/step]
014 Adjustment: Gamma *ENG
[0 to 2.55 / 0 / 0.01 mg/cm
2
/kV /step]
015 Adjustment: Vcnt Result *ENG
[0 to 9 / 9 / 1 /step]
[HST Control: M]
3713
Displays the factory settings of the cyan PCU.

Table of Contents