SERVICE CALL CONDITIONS
G104 4-16 SM
Item
SC
Symptom Possible Cause/Required Action
[0801, 0804, 0807, 0808, 0809, 80A] Self-diagnostic error– CPU: Detailed error
code
An error occurs when
checking the TLB.
Defective CPU devices
1. Replace the controller board.
[4002-4005] Self-diagnostic error– CPU: Detailed error code
The calculation error in the
CPU occurs.
Defective CPU
1. Replace the CPU.
[0B00] Self-diagnostic error - ASIC
ASIC and CPU timer error
detected during self-
diagnostic.
Defective controller
1. Replace the controller if the error is frequent.
[0D05] Self-diagnostic error– ASIC
821
[D]
The CPU checks if the
ASIC timer works properly
compared with the CPU
timer. If the ASIC timer
does not function in the
specified range, this SC
code is displayed.
System firmware problem
Defective RAM-DIMM
Defective controller
1. Reinstall the controller system firmware.
2. Replace the RAM-DIMM.
3. Replace the controller board.
[3003] Self-diagnostic error– HDD: Time out error
When the main switch is
turned on or starting the
self-diagnostic, the HDD
stays busy for the specified
time or more.
Loose connection
Defective HDD
Defective controller
1. Check that the HDD is properly connected to the
controller.
2. Replace the HDD.
3. Replace the controller.
[3004] Self-diagnostic error– HDD: Command error
822
[B]
When the main switch is
turned on or starting the
self-diagnostic, the
diagnostic error from HDD
occurs.
Defective HDD
1. Replace the HDD.
[6101] Self-diagnostic error – NIC: MAC address check sum error
The result of the MAC
address check sum does
not match the check sum
stored in ROM.
Defective controller
1. Replace the controller.
[6104] Self-diagnostic error – NIC: PHY IC error
The PHY IC on the
controller cannot be
properly recognized.
Same as [6101]
[6105] Self-diagnostic error – NIC: PHY IC loop back error
823
[B]
An error occurred during
the loop-back test for the
PHY IC on the controller.
Same as [6101]