SERVICE MODE TABLE
G104 5-16 SM
[Fusing Temp.] Fusing Temperature
(Paper Type, Mode, Color, Process Speed)
Paper Type -> N: Plain paper 1, N2: Plain paper 2, TC: Thick, TN: Thin, SP:
Special, OHP
Mode -> Simple [one-sided] or Duplex
Color -> K: Black only, FC: Full color
Process Speed -> LS: Low speed, RS: Regular speed
Reload: Print ready, between jobs
1105
Adjusts the fusing unit temperature for each mode.
1105 022 Reload Temp. *EGB
[100 to 200 / 160 / 1°C/step]
1105 025 TC1: Simple: [K] *EGB
1105 026 TC1: Duplex: [K] *EGB
1105 027 TC1: Simple: [FC] *EGB
1105 028 TC1: Duplex: [FC] *EGB
1105 029 TC2: Simple: [K] *EGB
1105 031 TC2: Simple: [FC] *EGB
[120 to 180 / 160 / 1°C/step]
1105 033 N: Simple: [K]: LS *EGB
[120 to 180 / 145 / 1°C/step]
1105 034 N: Simple: [K]: RS *EGB
[120 to 180 / 160 / 1°C/step]
1105 035 N: Duplex: [K]: LS *EGB
[120 to 180 / 145 / 1°C/step]
1105 036 N: Duplex: [K]: RS *EGB
[120 to 180 / 160 / 1°C/step]
1105 037 N: Simple: [FC]: LS *EGB
[120 to 180 / 145 / 1°C/step]
1105 039 N: Simple: [FC]: RS *EGB
[120 to 180 / 160 / 1°C/step]
1105 040 N: Duplex: [FC]: LS *EGB
[120 to 180 / 145 / 1°C/step]
1105 042 N: Duplex: [FC]: RS *EGB
[120 to 180 / 160 / 1°C/step]
Check Temp. Time *EGB [0 to 10 / 2.0 / 0.1 sec/step] 1105 043
Adjusts the rotation time before checking the fusing unit temperature. If the main
switch is turned on and off for a short time, it might be possible that the checked
temperature is high even though the whole of the fusing unit is not high enough
for printing condition.
1105 049 N2: Simple: [K]: LS *EGB
[120 to 180 / 150 / 1°C/step]
1105 050 N2: Simple: [K]: RS *EGB
[120 to 180 / 165 / 1°C/step]
1105 051 N2: Duplex: [K]: LS *EGB
[120 to 180 / 150 / 1°C/step]
1105 052 N2: Duplex: [K]: RS *EGB
[120 to 180 / 165 / 1°C/step]
1105 053 N2: Simple: [FC] LS *EGB
[120 to 180 / 150 / 1°C/step]
1105 054 N2: Simple: [FC] RS *EGB
[120 to 180 / 165 / 1°C/step]
1105 055 N2: Duplex: [FC] LS *EGB
[120 to 180 / 150 / 1°C/step]
1105 056 N2: Duplex: [FC] RS *EGB
[120 to 180 / 165 / 1°C/step]
1105 057 TN: Simple: [K]: LS *EGB
[120 to 180 / 135 / 1°C/step]
1105 058 TN: Simple: [K]: RS *EGB
[120 to 180 / 150 / 1°C/step]
1105 059 TN: Duplex: [K]: LS *EGB
[120 to 180 / 135 / 1°C/step]
1105 060 TN: Duplex: [K] RS *EGB
[120 to 180 / 150 / 1°C/step]
1105 061 TN: Simple: [FC] LS *EGB
[120 to 180 / 135 / 1°C/step]
1105 062 TN: Simple: [FC] RS *EGB
[120 to 180 / 150 / 1°C/step]
1105 063 TN: Duplex: [FC] LS *EGB
[120 to 180 / 135 / 1°C/step]
1105 064 TN: Duplex: [FC] RS *EGB
[120 to 180 / 150 / 1°C/step]
1105 065 SP1: Simple: [K] LS *EGB
[120 to 180 / 165 / 1°C/step]
1105 067 SP1: Duplex: [K] LS *EGB
[120 to 180 / 165 / 1°C/step]