SERVICE MODE TABLE
SM 5-17 G104
Service
Tables
1105 069 SP1: Simp.: [FC] LS *EGB
[120 to 180 / 165 / 1°C/step]
1105 071 SP1: Dupl.: [FC] LS *EGB
[120 to 180 / 165 / 1°C/step]
1105 089 OHP: [K]: LS *EGB
[120 to 180 / 160 / 1°C/step]
1105 090 OHP: [FC]: LS *EGB
[120 to 180 / 160 / 1°C/step]
1106
[Fusing Temp.] Fusing Temperature
H. Roller: Heat Roller
1106 002 H. Roller Temp.
Displays the heating roller temperature at
this time.
[0 to 230 / 0 / 1°C/step]
1911
[Print Speed Ctl] Print Speed Control for small paper sizes (A5 or smaller)
(Sheets of paper, Interval time or Temperature, Process Speed)
Simple [one-sided] or Duplex
Process Speed -> LS: Low speed, RS: Regular speed
See section 6 for more about these SPs.
1911 001 PPM Down: RS: S *EGB
1911 002 PPM Down: LS: S *EGB
The print speed (PPM) is reduced after the
machine has printed this number of pages
continuously.
[0 to 99 / 15 / 1 sheet/step]
1911 003 PPM Down Inter. *EGB
The print speed goes back to the normal
speed after this interval.
[0 to 255 / 30 / 1 sec/step]
1911 004 S-size Temp. 1 *EGB
The temperature is decreased by this
amount to prevent overheating the fusing
unit for small size paper.
[0 to 200 / 2 / 1°C/step]
1911 006 S-size Temp. 2 *EGB
1911 008 S-size Temp. 3 *EGB
[0 to 200 / 5 / 1°C/step]
1911 014 S-size Temp.: S1 *EGB
These SPs control when the above
temperature reductions are done.
[0 to 255 / 30 / 1 sheet/step]
1911 016 S-size Temp.: S2 *EGB [0 to 255 / 20 / 1 sheet/step]
1911 018 S-size Temp.: S3 *EGB [0 to 255 / 50 / 1 sheet/step]
1911 021 Simple Temp. 1 *EGB
Adjusts the temperature reduction for one-
sided printing.
[0 to 200 / 2 / 1°C/step]
1911 022 Simple Temp. 2 *EGB
[0 to 200 / 5 / 1°C/step]
1911 023 Simple Temp.:S1 *EGB
These SPs control when the above
temperature reductions are done.
[0 to 500 / 100 / 1 sheet/step]
1911 024 Simple Temp.:S2 *EGB [0 to 500 / 30 / 1 sheet/step]
1911 025 Duplex Temp. 1 *EGB
Adjusts the temperature reduction for duplex
printing.
[0 to 200 / 2 / 1°C/step]
1911 026 Duplex Temp. 2 *EGB
[0 to 200 / 5 / 1°C/step]
1911 027 Duplex Temp.: S1 *EGB
These SPs control when the above
temperature reductions are done.
[0 to 500 / 80 / 1 sheet/step]