SERVICE MODE TABLE
G104 5-20 SM
1917 014 TC1: H: Temp. Dec. *EGB
Adjusts the temperature decrease for thick
paper 1 at high temperature.
[-50 to 0 / 0 / 1 sec/step]
1917 015 TC1: L: Temp. Inc. *EGB
Adjusts the temperature increase for thick
paper 1 at low temperature.
[0 to 30 / 7 / 1°C/step]
1917 016 TC2: H: Temp. Dec. *EGB
Adjusts the temperature decrease for thick
paper 2 at high temperature.
[-50 to 0 / 0 / 1 sec/step]
1917 017 TC2: L: Temp. Inc. *EGB
Adjusts the temperature increase for thick
paper 2 at low temperature.
[0 to 30 / 7 / 1°C/step]
1917 018 OHP: H: Temp. Dec. *EGB
Adjusts the temperature decrease for OHP at
high temperature.
[-50 to 0 / 0 / 1 sec/step]
1917 019 OHP: L: Temp. Inc. *EGB
Adjusts the temperature increase for OHP at
low temperature.
[0 to 30 / 7 / 1°C/step]
1917 020 SP: H: Temp. Dec. *EGB
Adjusts the temperature decrease for special
paper at high temperature.
[-50 to 0 / 0 / 1 sec/step]
1917 021 SP: L: Temp. Inc. *EGB
Adjusts the temperature increase for special
paper at low temperature.
[0 to 30 / 7 / 1°C/step]