SERVICE MODE TABLE
SM 5-19 G104
Service
Tables
1916 [Nip Measure] Fusing Nip Width Measurement DFU
Nip Measure Exe. [0 or 1 / 0 /-]
0: Not execute, 1: Execute
1916 001
Performs the nip width measurement.
Prerotation Time *EGB [0 to 60 / 10 / 1 sec/step] 1916 002
Adjusts the rotation time of the fusing unit rollers before the nip measurement.
1917
[Environ. Adapt.] Fusing Idling: Environment Correction
The machine automatically adjusts the duration of fusing idling, depending on
room temperature measured by the temperature/humidity sensor
(Paper Type, Temperature Environment, Value of Temperature/ Rotation Time)
Paper Type ->N1: Plain paper 1, N2: Plain paper 2, T1: Thick paper 1, T2: Thick
paper 2, SP: Special (see the Specifications table for details on these paper
weights)
Temperature Environment -> H: High temperature, L: Low temperature
Value of Temperature/ Time: Dec.: Decrease, Inc.: Increase
1917 003 H: Rotat. Time Dec. *EGB
Adjusts the rotation time decrease at high
temperature.
[-120 to 0 / 0 / 1 sec/step]
1917 004 N1: H: Temp. Dec. *EGB
Adjusts the temperature decrease for plain
paper 1 at high temperature.
[-50 to 0 / 0 / 1°C/step]
1917 005 N1: L: Temp. Inc. *EGB
Adjusts the temperature increase for plain
paper 1 at low temperature.
[0 to 30 / 7 / 1°C/step]
1917 006 L: Rotat. Time Inc. *EGB
Adjusts the rotation time increase at low
temperature.
[0 to 120 / 0 / 1 sec/step]
1917 007 H: Standard Temp. *EGB
Sets the threshold temperature detected as
high temperature.
[25 to 40 / 30 / 1°C/step]
1917 008 L: Standard Temp. *EGB
Sets the threshold temperature detected as
low temperature.
[-15 to 30 / 18 / 1°C/step]
1917 009 L: Rotation Dec. *EGB
Adjusts the rotation time decrease at low
temperature.
[0 to 100 / 20 / 1 sec/step]
1917 010 N2: H: Temp. Dec. *EGB
Adjusts the temperature decrease for plain
paper 2 at high temperature.
[-50 to 0 / 0 / 1 sec/step]
1917 011 N2: L: Temp. Inc. *EGB
Adjusts the temperature increase for plain
paper 2 at low temperature.
[0 to 30 / 10 / 1°C/step]
1917 012 TN: H: Temp. Dec. *EGB
Adjusts the temperature decrease for thin
paper at high temperature.
[-50 to 0 / 0 / 1 sec/step]
1917 013 TN: L: Temp. Inc. *EGB
Adjusts the temperature increase for thin
paper at low temperature.
[0 to 30 / 7 / 1°C/step]