SERVICE MODE TABLE
G104 5-40 SM
2652
[Switch Timing] Switch timing from leading edge to normal, thin paper
(Paper Type, Edge) Paper Type -> TN: Thin, LE: Leading Edge
2652 002 T. Roll 2: Thin: LE *EGB [0 to 200 / 10 / 1 mm/step]
2652 003 Separation: TN: LE *EGB [0 to 200 / 25 / 1 mm/step]
2653
[Thin: [K]: TE] Transfer roller current and discharge plate voltage for the trailing
edge area, thin paper, black toner
2653 003 Separation *EGB
2653 007 Transfer Roller2 *EGB
[0 to 400 / 100 / 5%/step]
2654
[Switch Timing] Switch timing from normal to trailing edge, thin paper
(Paper Type, Edge) Paper Type -> TN: Thin, TE: Trailing Edge
2654 002 T. Roll 2: Thin: TE *EGB [0 to 200 / 10 / 1 mm/step]
2654 003 Separation: TN: TE *EGB [0 to 200 / 30 / 1 mm/step]
2656
[Thin: [FC]: LE] Transfer roller current and discharge plate voltage for the
leading edge area, thin paper, CMY toner
2656 003 Separation *EGB [0 to 400 / 200/ 5%/step]
2656 007 Transfer Roller2 *EGB [0 to 400 / 100 / 5%/step]
2658
[Thin: [FC]: TE] Transfer roller current and discharge plate voltage for the
trailing edge area, thin paper, CMY toner
2658 003 Separation *EGB
2658 007 Transfer Roller2 *EGB
[0 to 400 / 100 / 5%/step]
2751
[Special: [K]] Transfer roller current and discharge plate voltage for the image
area, special paper, black toner
Paper Side: 1st or 2nd
2751 007 T.Roll 2: 1st *EGB Adjusts the transfer roller current.
[0 to 60 / 5.0 / 0.1 -µA/step]
2751 008 Separation: 1st *EGB Adjusts the discharge plate voltage.
[0 to 4 / 2.0 / 0.1 -KV/step]
2756
[Special: [FC]] Transfer roller current and discharge plate voltage for the image
area, special paper, CMY toner
Paper Side: 1st or 2nd
2756 013 T.Roll 2: 1st *EGB Adjusts the transfer roller current.
[0 to 60 / 5.0 / 0.1 -µA/step]
2756 014 Separation: 1st *EGB Adjusts the discharge plate voltage.
[0 to 4 / 2.0 / 0.1 -KV/step]