SERVICE MODE TABLE
SM 5-41 G104
Service
Tables
2771
[Special: [K]: LE] Transfer roller current and discharge plate voltage for the
leading edge area, special paper, black toner
Paper Side: 1st or 2nd
2771 003 Separation *EGB
2771 007 T.Roll 2: 1st *EGB
[0 to 400 / 100 / 5%/step]
2773
[Special: [K]: TE] Transfer roller current and discharge plate voltage for the
trailing edge area, special paper, black toner
Paper Side: 1st or 2nd
2773 003 Separation *EGB
2773 007 T.Roll 2: 1st *EGB
[0 to 400 / 100 / 5%/step]
2776
[SP: [FC]: LE] Transfer roller current and discharge plate voltage for the leading
edge area, special paper, CMY toner
Paper Side: 1st or 2nd
2776 003 Separation *EGB
2776 007 T.Roll 2: 1st *EGB
[0 to 400 / 100 / 5%/step]
2778
[SP: [FC]: TE] Transfer roller current and discharge plate voltage for the trailing
edge area, special paper, CMY toner
Paper Side: 1st or 2nd
2778 003 Separation *EGB
2778 007 T.Roll 2: 1st *EGB
[0 to 400 / 100 / 5%/step]
2901
[T2: N: Size 4] Transfer Roller Current: Correction for Humidity, Plain paper 1,
Paper width between A5 and A6
(Environment, Process Speed, [Color], Paper Side)
LS: Low Speed, RS: Regular Speed, Paper Side: 1st or 2nd
2901 001 LL: RS [K]: 1st *EGB [0 to 1275 / 100 / 5%/step]
2901 002 LL: RS [K]: 2nd *EGB [0 to 1275 / 350 / 5%/step]
2901 003 LL: RS [FC]: 1st *EGB [0 to 1275 / 130 / 5%/step]
2901 004 LL: RS [FC]: 2nd *EGB [0 to 1275 / 170 / 5%/step]
2901 005 LL: LS [K]: 1st *EGB [0 to 1275 / 150 / 5%/step]
2901 006 LL: LS [K]: 2nd *EGB [0 to 1275 / 280 / 5%/step]
2901 007 LL: LS [FC]: 1st *EGB [0 to 1275 / 120 / 5%/step]
2901 008 LL: LS [FC]: 2nd *EGB [0 to 1275 / 170 / 5%/step]
2901 009 MM: RS [K]: 1st *EGB [0 to 1275 / 80 / 5%/step]
2901 010 MM: RS [K]: 2nd *EGB [0 to 1275 / 480 / 5%/step]
2901 011 MM: RS [FC]: 1st *EGB [0 to 1275 / 100 / 5%/step]
2901 012 MM: RS [FC]: 2nd *EGB [0 to 1275 / 190 / 5%/step]
2901 013 MM: LS [K]: 1st *EGB [0 to 1275 / 100 / 5%/step]
2901 014 MM: LS [K]: 2nd *EGB [0 to 1275 / 400 / 5%/step]
2901 015 MM: LS [FC]: 1st *EGB [0 to 1275 / 90 / 5%/step]
2901 016 MM: LS [FC]: 2nd *EGB [0 to 1275 / 180 / 5%/step]
2901 017 HH: RS [K]: 1st *EGB [0 to 1275 / 100 / 5%/step]
2901 018 HH: RS [K]: 2nd *EGB [0 to 1275 / 220 / 5%/step]