SERVICE MODE TABLE
G104 5-48 SM
3041 [Vtref] Vtref Setting ([Color])
3041 001 Lower Limit: [K] *EGB
3041 002 Lower Limit: [M] *EGB
3041 003 Lower Limit: [C] *EGB
3041 004 Lower Limit: [Y] *EGB
Sets the lower limit Vtref voltage for each
color.
[0.10 to 5.00 / 1.50 / 0.01 V/step]
3041 005 Upper Limit: [K] *EGB DFU
3041 006 Upper Limit: [M] *EGB
3041 007 Upper Limit: [C] *EGB
3041 008 Upper Limit: [Y] *EGB
Sets the maximum limit Vtref voltage for
each color.
[0.10 to 5.00 / 3.70 / 0.01 V/step]
3042 [Vtref] Vtref Correction Setting ([Color]) DFU
3042 001 Mode *EGB Sets the Vtref correction.
[0 or 1 / 1 / -] Alphanumeric
0: On, 1: Off
3042 002 Step [K] *EGB
3042 003 Step [M] *EGB
3042 004 Step [C] *EGB
3042 005 Step [Y] *EGB
Adjusts the Vtref correction step for each
color.
[0.00 to 1.00 / 0.10 / 0.01 V/step]
3042 014 Change Step: [K] *EGB
3042 015 Change Step: [M] *EGB
3042 016 Change Step: [C] *EGB
3042 017 Change Step: [Y] *EGB
Adjusts the density change rate of the ID
sensor pattern for each color.
[0 to 100 / 10 / 1%/step]
3101 [P. Sensor Patt.] ID Sensor Pattern Density Setting ([Color])
3101 001 Change Value: [K] *EGB
3101 002 Change Value: [M] *EGB
3101 003 Change Value: [C] *EGB
3101 004 Change Value: [Y] *EGB
Displays the density change rate of the ID
sensor pattern for each color.
[-100 to 100 / 0 / 1%/step]
3111 [Voff Display] Vsp-offset Display
3111 001 Regular *EGB Displays the Vsp-offset regular voltage.
[0.00 to 5.00 / 0.00 / 0.01 V/step]
3111 002 Diffusion *EGB Displays the Vsp-offset diffusion voltage.
[0.00 to 5.00 / 0.00 / 0.01 V/step]
3121 [Vsg Display] Vsg Display
3121 001 Regular *EGB Displays the Vsp regular voltage.
[0.00 to 5.00 / 0.00 / 0.01 V/step]
3121 002 Diffusion Displays the Vsp diffusion voltage.
[0.00 to 5.00 / 0.00 / 0.01 V/step]
3131 [Lps Display] Ips Display
3131 001 Lps *EGB Displays the Ips.
[0 to 511 / 0 / 1/step]