SERVICE MODE TABLE
SM 5-49 G104
Service
Tables
3141 [Vmin Display]
3141 001 [K] *EGB
3141 005 [Cl] *EGB
Displays the Vmin voltage for each color.
[0.00 to 5.00 / 0.00 / 0.01 V/step]
3142 [Kx Display]
3142 001 Min *EGB Displays the minimum Kx.
[0.0000 to 1.0000 / 0.0000 / 0.0001/step]
3143 [K5 Display] ([Color])
3143 002 [M] *EGB
3143 003 [C] *EGB
3143 004 [Y] *EGB
Displays the P.sensor K5 for each color.
[0.0000 to 5.0000 / 1.2500 / 0.0001/step]
3145 [Vmin]
3145 001 Upper Limit *EGB DFU
Adjusts the maximum Vmin.
[0.00 to 5.00 / 0.05 / 0.01 V/step]
3146 [K2]
3146 001 Upper Limit *EGB DFU
Adjusts the upper limit.
[0.0000 to 1.0000 / 0.1500 / 0.0001/step]
3146 002 Lower Limit *EGB DFU
Adjusts the lower limit.
[0.0000 to 1.0000 / 0.0500 / 0.0001/step]
3147 [K5]
3147 001 Upper Limit *EGB DFU
Adjusts the upper limit.
[0.0000 to 5.0000 / 2.5000 / 0.0001/step]
3147 002 Lower Limit *EGB DFU
Adjusts the lower limit.
[0.0000 to 5.0000 / 0.7500 / 0.0001/step]
3148 [P sensor Prm.] ID sensor Parameter
3148 001 setting *EGB DFU
[0 to 8.0000 / 4.600 / 0.001/step]
3151 [Vsg Display] ([Color])
3151 001 Regular: [K] *EGB
3151 002 Regular: [M] *EGB
3151 003 Regular: [C] *EGB
3151 004 Regular: [Y] *EGB
Displays the Vsg output from ID sensor for
each mode.
[0.00 to 5.00 / 0.00 / 0.01 V/step]