SERVICE MODE TABLE
G104 5-50 SM
3151 005 Diffusion: [K] *EGB
3151 006 Diffusion: [M] *EGB
3151 007 Diffusion: [C] *EGB
3151 008 Diffusion: [Y] *EGB
Displays the Vsg output from ID sensor for
each mode.
[0.00 to 5.00 / 0.00 / 0.01 V/step]
3161 [P. Pattern] ID Sensor Pattern Setting ([Color]) DFU
3161 001 Target Value: [K] *EGB
3161 002 Target Value: [M] *EGB
3161 003 Target Value: [C] *EGB
3161 004 Target Value: [Y] *EGB
Adjusts the target voltage of ID sensor
pattern for each mode.
[0 to 100 / 50 / 1%/step]
3171 [P. Pattern] ID Sensor Pattern Setting ([Color]) DFU
3171 001 Interval: [K] *EGB
3171 002 Interval: [MCY] *EGB
Adjusts the interval of making the ID sensor
pattern.
[0 to 200 / 60/ 1 sheet/step]
3201 [Toner Near End] Toner Near End ([Color]) DFU
3201 001 Sensor: [K]
3201 002 Sensor: [M]
3201 003 Sensor: [C]
3201 004 Sensor: [Y]
Displays the output from the toner end
sensor.
[0.0 to 5.0 / 0.0 / 0.1 V/step]
3202 [Toner Near End] Toner Near End ([Color])
3202 001 Counter: [K] *EGB
3202 002 Counter: [M] *EGB
3202 003 Counter: [C] *EGB
3202 004 Counter: [Y] *EGB
Displays the counter of the toner near end
for each mode.
[0 to 30 / 0 / 1/step]
3301 [Toner Mode] Toner Supply Control ([Color])
3301 001 [K] *EGB
3301 002 [M] *EGB
3301 003 [C] *EGB
3301 004 [Y] *EGB
Selects the method of the toner suppy for
each mode.
[0 to 3 / 3 / 1/step]
0: Fixed, 1: Coefficient (Pixel),
2: Coefficient (TD sensor), 3: Hybrid
6.2.5
3302 [Toner Mode] Toner Supply Control ([Color])
3302 001 Fixed Rate: [K] *EGB
3302 002 Fixed Rate: [M] *EGB
3302 003 Fixed Rate: [C] *EGB
3302 004 Fixed Rate: [Y] *EGB
Adjusts the toner supply rate for each mode.
These SPs are enabled only when SP3301
for each color is set to “0”.
[0 to 100 / 5 / 1%/step]
3303 [Toner Mode] Toner Supply Control ([Color])
3303 001 T. Supply Rate: [K] *EGB
Displays the toner supply rate for each