ENGINE SERVICE MODE
G104 5-58 SM
5302 [Set Time]
5302 002 Time difference *CTL#
Adjusts the RTC (real time clock) time setting
for the local time zone.
[-1440 to 1440 / NA, EU, CH / 1 minute/step]
NA: -300, EU: 60, CH: 480
5307 [Summer Time]
5307 001 Setting - Enables or disables the summer time mode.
[0 to 1 / 1 / -] Alphanumeric
0: Off, 1: On
5307 003 Rule Set(Start) -
Specifies the start of the daylight saving
time.
5307 004 Rule Set(End) - Specifies the end of the daylight saving time.
5404 [UcodeCtrClr] User Code Counter Clear
5404 001 UcodeCtrClr - Clears all counters for users.
5501 [PM Alarm] PM Alarm Level
5501 001 *CTL
Sets the PM alarm level. A PM alarm is
made when this condition occurs: PA x 1000
= or > PC, where PA is the value set in SP5-
501 and PC is the value in the PM counter.
[0 to 9999 / 0 / -]
The alert is sent to the e-mail address that is
specified for the system administrator using
a browser and the built-in web server (Web
Image Monitor).
0: Disables the PM alarm
When SP5-866-001 is set to 1, this SP is
enabled.
5504 [Jam Alarm]
5504 001 *CTL
Sets the jam alarm level. If a paper jam
occurs, the jam alarm counter increases by
+1. If no paper jam occurs while the set
number of paper is output, the jam alarm
counter decreases by -1. The jam alarm
occurs when the jam alarm counter gets to
+10.
[0 to 3 / 3 / 1/step]
0: Disables the jam alarm
1: 1.5K, 2: 3K, 3: 6K
The alert is sent to the e-mail address that is
specified for the system administrator using
a browser and the built-in web server (Web
Image Monitor).
When SP5-866-001 is set to 1, this SP is
enabled.