ENGINE SERVICE MODE
SM 5-59 G104
Service
Tables
5505 [Error Alarm]
5505 001 *CTL
Sets the error alarm level. If an SC code
occurs, the error alarm counter increases by
+1. If no SC code occurs while the set
number of paper is output, the jam alarm
counter decreases by -1. The error alarm
occurs when the error alarm counter reaches
+5.
[0 to 255 / 30 / 1/step]
0: Disables the PM alarm
The alert is sent to the e-mail address that is
specified for the system administrator using
a browser and the built-in web server (Web
Image Monitor).
When SP5-866-001 is set to 1, this SP is
enabled.
5507 [Supply Alarm]
5507 001 Paper Supply Ala *CTL
5507 003 Toner Supply Ala -
Enables or disables the supply alarm.
[0 to 1 / 0 / -] Alphanumeric
0: Off, 1: On
5507 128 Interval: Others *CTL
5507 133 Interval: A4 *CTL
5507 134 Interval: A5 *CTL
5507 142 Interval: B5 *CTL
5507 164 Interval: LG *CTL
5507 166 Interval: LT *CTL
5507 172 Interval: HLT *CTL
Sets the paper supply alarm level. A paper
supply alarm counter increases by +1 when
a sheet of the related size is used. The paper
supply alarm occurs when one of the paper
supply alarm counters gets to the set value.
[250 to 10000 / 1000 / 1/step]
The alert is sent to the e-mail address that is
specified for the system administrator using
a browser and the built-in web server (Web
Image Monitor).
When SP5-866-001 is set to 1, this SP is
enabled.
5801 [Memory Clear]
5801 001 All -
Resets the SP5801-002 through 016 except
the security related data in 003, 010, 011and
015. These cannot be reset with SP mode.
5801 002 Engine - Resets or deletes the engine-related data.
5801 003 SCS - Clears the system settings.
5801 004 IMH - Clears IMH data. DFU
5801 005 MCS - Clears MCS data. DFU
5801 008 PRT - Clears the printer application settings.
5801 010 Web Service *CTL
Clears the web service data and the network
application data.
5801 011 NCS *CTL
Initializes the system default and interface
settings (IP address also), SmartNetMonitor
for Admin, WebStatusMonitor settings, and
the TELNET settings.
5801 014 DCS Setting *CTL Resets or deletes the DCS-related data.