Service Call Conditions
SM 4-7 G160/G161
G160/G161
SC
[Level]
Symptom Possible Cause/Required Action
LDB unit turns on while the
polygon motor is rotating
normally.
FGATE: On error [K]
230
[C]
The PFGATE ON signal
does not assert within 5
seconds after processing the
image in normal job or
MUSIC for [K] starts.
Defective connection between the controller
board and EGB
Defective cable between the EGB and LDB
1. Check the connectors.
2. Replace the LDB.
3. Replace the EGB.
FGATE: Off error [K]
231
[C]
The PFGATE ON signal
still asserts within 5
seconds after
processing the image in
normal job or MUSIC for
[K] ends.
The PFGATE ON signal
still asserts when the
next job starts.
Defective connection between the controller
board and EGB
Defective cable between the EGB and LDB
1. Check the connectors.
2. Replace the LDB.
3. Replace the EGB.
FGATE: On error [Y]
232
[C]
The PFGATE register of
GAVD does not assert within
5 seconds after processing
the image in normal job or
MUSIC for [Y] started.
Same as SC 230
FGATE: Off error [Y]
233
[C]
The PFGATE ON signal
still asserts within 5
seconds after
processing the image in
normal job or MUSIC for
[K] ends.