Service Call Conditions
G160/G161 4-8 SM
SC
[Level]
Symptom Possible Cause/Required Action
The PFGATE ON signal
still asserts when the
next job starts.
FGATE: On error [M]
234
[C]
The PFGATE register of
GAVD does not assert within
5 seconds after processing
the image in normal job or
MUSIC for [M] started.
Same as SC 230
FGATE: Off error [M]
235
[C]
The PFGATE ON signal
still asserts within 5
seconds after
processing the image in
normal job or MUSIC for
[M] ends.
The PFGATE ON signal
still asserts when the
next job starts.
Same as SC 231
FGATE: On error [C]
236
[C]
The PFGATE register of
GAVD does not assert within
5 seconds after processing
the image in normal job or
MUSIC for [C] started.
Same as SC 230
FGATE: Off error [C]
237
[C]
The PFGATE ON signal
still asserts within 5
seconds after
processing the image in
normal job or MUSIC for
[C] ends.
The PFGATE ON signal
Same as SC 231