Service Call Conditions
G160/G161 4-14 SM
SC
[Level]
Symptom Possible Cause/Required Action
Drum gear position sensor error
380
[C]
When receiving the input
signal of drum gear position
sensor is not correctly done,
SC380 is logged.
Dirty or defective drum gear position sensor
1. Clean the drum gear position sensor.
2. Replace the drive unit.
Drum motor error [K]
396
[D]
The LOCK signal is not
detected for 2 seconds more
while the start signal of the
drum motor for black PCU is
output.
OPC motor slip due to the excessive load
1. Clean the PCU.
2. Check the cable from the Black OPC/
Development motor. Replace it if
necessary.
3. Replace the EGB.
4. Replace the Black OPC/Development
motor.
Drum motor error [CMY]
397
[D]
The LOCK signal is not
detected for 2 seconds more
while the start signal of the
drum motor for color PCU is
output.
Same as SC 396
ID sensor correction error
400
[D]
Regular Vsp is not (4 ±0.5V)
when ID sensor correction is
executed.
Defective ID sensors
Dirty ID sensors or transfer belt
ID sensor life is over.
1. Replace the ID sensors.
ID sensor: LED adjustment error
418
[D]
LED PWM adjustment is not
[A] for three times
consecutively.
[A] = 50 < [A] < 400
Defective ID sensors
Dirty ID sensors or transfer belt
ID sensor life is over.
1. Replace the ID sensors.
Transfer belt contact error
442
[D]
The transfer belt contact
sensor does not detect the
Dirty transfer belt contact sensor
Defective transfer belt contact motor