Service Call Conditions
G160/G161 4-22 SM
SC
[Level]
Symptom Possible Cause/Required Action
[06FF]: Detailed error code
[B]
The pipeline clock frequency
rate is different from the
prescribed value.
Defective CPU devices
Mode bit data error, which is used for
initializing CPU.
1. Replace the controller board.
[0702]: Detailed error code
[B]
The result when the program
is executed in the command
cache is different from
desirable value.
Insufficient CPU cache
Insufficient memory process speed
1. Replace the controller board.
2. Replace the RAM DIMM.
[0709, 070A]: Detailed error code
[B]
Even you write the data in the
only cache of memory, the
data is actually written in
another area (not cache) of
memory.
Defective CPU devices
Incorrect SPD
Boot mode setting error
1. Replace the controller board.
2. Replace the RAM DIMM.
[0801, 0804, 0807, 0808, 0809, 80A]: Detailed error code
[B]
An error occurs when
checking the TLB.
Defective CPU devices
1. Replace the controller board.
[4002-4005]: Detailed error code
[B]
The calculation error in the
CPU occurs.
Defective CPU
1. Replace the CPU.
821 Self-Diagnostic Error: ASIC
ASIC error
[0B00]
[B]
The write-&-verify check error
has occurred in the ASIC.
Defective controller board
1. Replace the controller.
ASIC not detected
[0B06]
[B]
The ASIC of the I/O is not
detected.
ASIC (controller board defective)
Poor connection between North Bridge and
PCI I/F.
1. Replace controller board.
SHM register check error [0B10]
[B]
Failed to initialize or could not Defective bus connection
CÓPIA NÃO CONTROLADA