Service Call Conditions
SM 4-23 G160/G161
G160/G161
SC
[Level]
Symptom Possible Cause/Required Action
read connection bus. Data in
SHM register incorrect.
Defective SHM
1. Replace controller board
Timer error between ASIC and CPU
[0D05]
[B]
The CPU checks if the ASIC
timer works properly
compared with the CPU
timer. If the ASIC timer does
not function in the specified
range, this SC code is
displayed.
System firmware problem
Defective RAM-DIMM
Defective controller
Reinstall the controller system firmware.
1. Replace the RAM-DIMM.
2. Replace the controller board.
822 Self-Diagnostic Error: HDD
Timeout error/ [3004]: Command error
[3003]
[B]
When the main switch is
turned on or starting the
self-diagnostic, the HDD
stays busy for the specified
time or more.
Loose connection
Defective HDD
Defective controller
1. Check that the HDD is correctly
connected to the controller.
2. Replace the HDD.
3. Replace the controller.
823 Self-diagnostic Error: NIB
MAC address check sum error
[6101]
[B]
The result of the MAC
address check sum does not
match the check sum stored
in ROM.
Defective controller
1. Replace the controller.
PHY IC error
[6104]
[B]
The PHY IC on the controller
cannot be correctly
recognized.
Same as SC823-[6101]
PHY IC loop-back error
[6105]
[B]
An error occurred during the
loop-back test for the PHY IC
on the controller.
Same as SC823-[6101]