Service Mode Table
SM 5-119 G160/G161
G160/G161
5848 009 ac: Job Ctrl
5848 011 ac: Dev Mng *CTL
5848 022 ac:Uadmin *CTL
Switches access control on and off.
0000: OFF, 0001: ON
5848 210 LogType: Job 1 *CTL
5848 211 LogType: Job 2 *CTL
5848 212 LogType: Access *CTL
5848 213 PrimarySrv *CTL
5848 214 SecondarySrv *CTL
5848 215 Start Time *CTL
Displays the log server settings.
These can be adjusted with the Web Image
Monitor.
Interval Time *CTL
[1 to 1000 / 1 / 1 hour/step]
5848 216
Specifies the interval of transmitting log information. This SP is activated only
when the SP5848-217 is set to "2".
5848 217 Timing *CTL
[0 to 2 / 0 / 1 /step]
Selects the method for transmitting log information.
0: Transmitting OFF, 1: Always Transmitting, 2: Interval Transmitting
5849 [Installation Date]
5849 001 Display *CTL
Enables or disables the udirectory access
limitation.
0000: Disabled, 0001: Enabled
5849 003 Total Counter *CTL
5851 [Bluetooth]
5851 001 Mode *CTL
Adjusts the Bluetooth setting.
[0 or 1 / 0 / -]
0: Public, 1: Private
5856 [Remote ROM Update]
5856 002 Local Port
Allows the technician to update the firmware
using a parallel cable.
[0 or 1 / 0 / 1/step]
0: Disable, 1: Enable
5857 [Debug Log Save]
5857 001 ON/ OFF *CTL Enables Or Disables The Debug Log Saving