Service Mode Table
G160/G161 5-126 SM
5990 007 NIB Summary Prints the network configuration report.
SP7-XXX (Data Log)
7401 [Total SC Counter]
7401 001 Total SC Counter *CTL
Displays the number of SC codes detected.
[0 to 9999 / 0 / 1/step]
7403 [SC History]
7403 001 Latest *CTL
7403 002 Latest 1 *CTL
7403 003 Latest 2 *CTL
7403 004 Latest 3 *CTL
7403 005 Latest 4 *CTL
7403 006 Latest 5 *CTL
7403 007 Latest 6 *CTL
7403 008 Latest 7 *CTL
7403 009 Latest 8 *CTL
7403 010 Latest 9 *CTL
Displays the SC codes detected.
The 10 most recently detected SC Codes are
displayed on the screen, and also can be
seen on the SMC (logging) outputs.
7502 [Total Paper Jam Coun]
7502 001 Total Paper Jam *CTL
Displays the total number of jams detected.
[0 to 9999 / 0 / 1 sheet/step]
[Paper Jam/Loc] Paper Jam Location
7504
Displays the number of jams according to the location where jams were
detected.
7504 001 At Power On *CTL Not used
7504 003 Tray 1: Non-feed *CTL Tray 1: Paper is not fed.
7504 004 Tray 2: Non-feed *CTL Tray 2: Paper is not fed.
7504 005 Tray 3: Non-feed *CTL Tray 3/LCT: Paper is not fed.
7504 006 By-pass: Non-feed *CTL By-pass: Paper is not fed.
7504 007 Duplex: Non-feed *CTL Duplex: Paper is not fed.
7504 008 Registration *CTL Registration Senor does not get "ON".
7504 009 Fusing Unit *CTL Fusing Exit Sensor does not get "ON".