PCDU
G179 3-14 SM
2. Toner cap [A]
3. Insert cap [A] into the opening of the PCDU [B].
Make sure that the cap is inserted completely into the opening.
4. Remove the spring [C] on the rear side of the PCDU.
5. Remove the spring [D] on the front side of the PCDU and attach it to the hooks as
shown.
To prevent breaking the weaker hook , use a pair of needle-nose pliers to
disconnect the spring at , remove the spring, then re-attach to and .
When you move this spring, this retracts the movable drum cleaning blade so that
it does not touch the surface of the drum when the drum is re-installed.