SC Tables: SC9xx
G179 4-40 SM
4.12 SC TABLES: SC9XX
Electrical total counter error
The total counter contains something that is not a number.
900
CTL
D
NVRAM incorrect type
NVRAM defective
NVRAM data scrambled
Unexpected error from external source
Printer error 1
An internal application error was detected and operation cannot continue.
920
CTL
B
Software defective; turn the machine off/on, or change the controller
firmware
Insufficient memory
Printer font error
A necessary font is not found in the SD card.
921
CTL
D
A necessary font is not found in the SD card.
The SD card data is corrupted.
Software error 1
The software performs an unexpected function and the program cannot
continue.
990
CTL
D
Software defective, re-boot
Software error 2
991 CTL
C
The software performs an unexpected function. However, unlike SC990,
recovery processing allows the program to continue.