Blown Fuse Conditions
SM 4-47 G179
Trouble-
shooting
4.14 BLOWN FUSE CONDITIONS
Rating
Fuse
115V 210 to 230V
Symptom at power on
Power Supply Board
FU21 6.3A / 125V 6.3A / 250V SC 533 (Power to IOB)
FU23 10A / 125V 10A / 250V
"Open Cover" is displayed.
(Power to Interlock Switch)
FU24 10A / 125V 10A / 250V
"Open Cover" is displayed.
(Power to Interlock Switch)
FU25 6.3A / 125V 6.3A / 250V
Alert LED turns on and operation panel does
not turn on. (Power to MB)
FU26 6.3A / 125V 6.3A / 250V
The stack of paper in the optional paper feed
unit or LCT is not detected. SC 503 is issued
after opening and closing the tray 3 or 4.
(Power to optional PFU or LCT)
FU27 6.3A / 250V 6.3 A/ 250V
The machine does not detect a finisher.
(Power to optional Finisher)
FU101 15A / 125V 8A / 250V No response
FU102 12A / 125V 4A / 250V No response