Updating the Firmware
SM 5-159 G179
Service
Tables
Recovery after Power Loss
If the ROM update is interrupted as a result of accidental loss of power while the firmware
is updating, then the correct operation of the machine cannot be guaranteed after the
machine is switched on again. If the ROM update does not complete successfully for any
reason, then in order to ensure the correct operation of the machine, the ROM update error
will continue to show until the ROM is updated successfully.
In this case, insert the card again and switch on the machine to continue the firmware
download automatically from the card without the menu display.
5.27.4 PRINTING THE SELF-DIAGNOSIS REPORT
The Self-Diagnosis Report, printed with SP5990 (SP Print Mode), lists the current names
and version numbers of the update modules.
1. To enter the SP mode, push and hold down "$ for 5 sec. then push [OK].
2. Push $ to display "2. Engine" then push [OK].
3. Push $ to display "5. Mode" then push [OK].
5.001 All Indicators On
4. Push $ once to select SP5990 then push [OK].
5.990.001 All
5. Push $ three times to select SP5990-005 then push [OK].
5.990.005 Diagnostic Report
EXECUTE
6. Push [#Enter] to print the report.
The firmware module names and version numbers are listed in the report.
5.27.5 HANDLING FIRMWARE UPDATE ERRORS
An error message shows in the first line if an error occurs during a download. The error
code consists of the letter “E” and a number (“E20”, for example).