Loading...
Using Debug Log
SM 5-169 G179
Service
Tables
To Select the Target for the Debug Log File
You can select either the HDD (default) or the SD card as the target. This procedure shows
you how to select the SD card.
1. Enter SP5857-002
2. Select "2 (HDD)" or "3 (SD)" as the target.
3. Push the "Escape" button to return to the SP mode menu.
4. Do the next procedure to select the events that you want to record in the debug log file.
To Select Events
Here is a list of the events that you can select. Any number of events can be selected.
SP No. Name What It Does
SP5858-001 EngineSC Error
Saves error data when an engine-related SC
code occurs.
SP5858-002 SystemSC Error
Saves error data when a controller-related SC
Code occurs.
SP5858-003 Any SC Error
Saves error data only for the SC code that you
specify by manually entering the SC code
number.
SP5858-004 Jam Saves error data for jams.
- Example 1: To Select Items 001, 002, or 004 -
1. Push " or $ to select 001, 002, or 003. This example shows the selection of 001.
5.858.001 Engine SC
0
(0)
2. Push the "OK" button, and then select "1 (ON)" with the " or $ button.
3. Push the "OK" button again.
4. Push the "Escape" button to return to the SP mode menu.
5. Repeat this procedure to select either 002 or 004.
- Example 2: To set an SC code with 003 -