Service Maintenance Parts – Mainframe
SM 2-1 G179
Preventive
Maintenance
2. PREVENTIVE MAINTENANCE
2.1 SERVICE MAINTENANCE PARTS – MAINFRAME
Preventive maintenance for this machine may be performed by the customer or by the
service professional. If preventive maintenance is performed by the customer, there are
two maintenance kits, Maintenance Kit A contains the PDCU and Maintenance Kit B
contains a Fusing Unit and Transfer Belt Unit. Instructions for the customer maintenance
procedures are included with the maintenance kits.
Service professionals should follow the PM procedures in this manual for preventive
maintenance.
2.1.1 PM PARTS TABLES FOR MAINFRAME
Amounts mentioned as the PM interval indicate the number of prints.
Symbol key: C: Clean, R: Replace, L: Lubricate, I: Inspect
G179 EM 160K 320K 800K Note
Drum (OPC) Area
OPC Drum I R
Charge Roller R
Charge Roller Cleaning
Roller
R
Drum Cleaning Blade 1 R
Drum Cleaning Blade 2 R
Quenching Lamp C C Dry cloth
Pick-off Pawls R
Spurs C C Dry cloth
ID Sensor C C Perform SP3-001-2 after