SC Tables: SC9xx
SM 4-41 G179
Trouble-
shooting
Software defective, re-boot
In order to get more details about SC990 and SC991:
1) Execute SP7403 or print an SMC Report (SP5990) to read the history of the 10 most
recent logged errors.
2) If you press the zero key on the operation panel with the SP selection menu displayed,
you will see detailed information about the recently logged SC990 or SC991, including the
software file name, line number, and so on.
1) is the recommended method, because another SC could write over the
information for the previous SC.
Undefined error
Defective software program
992
CTL
D
An error undetectable by any other SC code occurred
Software Error 4: Application cannot start
Register processing does not operate for an application within 60 s after
the machine power is turned on. No applications start correctly, and all end
abnormally.
998
CTL
D
Software bug
A RAM or DIMM option necessary for the application is not installed or
not installed correctly.