Duplex
G179 3-48 SM
7. Keep the right door fully open.
8. Push up the duplex unit a little bit, while pressing the bracket [D] to lock the spring [E].
Do not let the duplex unit open fully before releasing the wire (step 9).
Otherwise, the lock for the spring [E] is released.
9. Wire [F] ( x 1)
10. Push the projection [G].
11. Duplex unit ( x 3, ground cable x 1)