Engine SP1-xxx: Feed-1
G179 5-10 SM
Fusing Idling
1103*
Switches fusing idling on/off. When on, printing will not start until enough
time has elapsed so the hot roller can reach optimum temperature. This
ensures even heat on the hot roller.
Switch on if fusing on the 1st and 2nd prints is incomplete (this may occur if
the room is cold.). You must switch SP1103-1 ON before you set the fusing
interval with SP1103-2.
001 Enable Fusing Idling
0 = Off, 1 = On
002 Interval
[0 to 60 / 30 / 1 sec.]
003 Idl Time at Every Job
Sets the machine to fusing idling only for 30
sec. for every job (when the original is set on
the ARDF, when the ARDF cover is opened,
etc.) and the fusing unit has reached the
reload temperature (optimum temperature for
operation).
[0 to 30 / 0 / 1 sec.]
0: No idling done before a job.
Fusing Temp. Cont
On-Off/Phase
1104*
Selects the fusing temperature control method. After changing this setting,
be sure to turn the machine off and on again with the main power switch to
enable the new setting.
[0 to 1 / 0 / 1]
0: Normal (ON/OFF control). Allows full application from ac power supply to
bring the hot roller up to the target fusing temperature then shuts off.
Determines the on-time from the present temperature (detected by the
thermistor on the hot roller) and the temperature of 1 cycle before.
1: Phase (hysterisis) control. Sets the upper and lower limits for the
temperature; at the lower temperature the fusing lamp is on and at the
higher temperature the fusing lamp is off.
Change this setting to “0” only if the user has excessive electrical noise or