SP1-xxx: Feed-2
SM 5-19 G179
Service
Tables
edge detection and leading edge detection is within the value of this setting,
the machine determines that the paper is still being fed.
Web Mot Set: Web End
[0 to 60 / 27 / 1 sec]
008
Adjusts the motor rotation time after the web end.
Web Mot Rotat: P. On
[0 to 10 / 2 / 1 times]
009
Adjusts the number of web motor rotations at the re-load state.
Web Mot Int: Pre-idle
[0 to 30 / 5 / 1 sec]
010
Adjusts the motor waiting time after the fusing motor idling.
Web Mot Rotat: Pre-idle
[0 to 10 / 2 / 1 times]
011
Adjusts the number of web motor rotations at the fusing idling state.
1903 Clean Web Setting
Total Paper Count
[0 to 999999999 / 0 / 1 sec]
001
Displays the total paper feeding time.
Total Web Mot Dri Time
[0 to 999999999 / 0 / 1 sec]
002
Displays the total time of web motor rotation.
1907* P Feed Timing Adj. (DFU)
001 Feed Sol ON: Plain
002 Feed Sol ON: Thick
[-10 to 40 / 0 / 2.5 mm]
003 Feed Sol OFF: Plain
004 Feed Sol OFF: Thick
005 Feed Cl ON: Plain
006 Feed Cl ON: Thick
[-10 to 10 / 0 / 1 mm]